SSD Series Refrigeration Air Dryer
Capacity: 0.6~4.0 m3/min
Max. working pressure : ≤1.6MPa (16barg)
Max. inlet temperature : 60℃
Max. ambient temperature : 50℃
Min. ambient temperature : 5℃
Cooling type: air-cooled
Power supply: 220V/1Ph/50Hz or 60Hz
Refrigerant: R134a / R407C
Rated condition:
Rated working pressure : 0.7MPa
Inlet temperature : 38℃
Ambient temperature : 38℃
PDP : 3-10℃
Other :
For pressure of < 0.4MPa or > 2.0MPa
please contact us
When the working pressure > 1.6Mpa
the electrical drain needs to be replaced
Sturdy and durable
Different from Carbon steel material product.
Using 304S stainless steel for heat exchanger, water separator and air connections can avoid the secondary pollution to air quality, so the SSD series dryer can be directly used for food ,medicine, semiconductor, senior spraying field and etc.
Nano anticorrosive coating on air condenser makes the useful life longer.
Energy saving and environmental protection
Heat exchanger is following Europe and America advanced plate-fin structure, highly heat-efficiency;
The inlet and outlet temperature difference of pre-cooler is 3-5℃, which is much more better than the similar products and minimize the outlet relative humidity and avoid condensation in the piping.
Outlet compressed air relative humidity is low, the below air pipe surface without Condensation phenomenon.
The pre-cooler reclaim nearly 90% compressed air, and greatly reduces the evaporator load, so the power consumption of the refrigerant compressor is low, only 70% of the normal one.
Friendly refrigerant is adopted for all series dryers.
Security and Reliability
Multiple overload protection.
Newest CE certificate.
Technical Specification
Model |
Air Connection |
Capacity | Dimension mm |
Weight (kg) |
Recommended Pre-Filter Model |
Recommended After-Filter Model |
|||
m³/min | CFM | L | W | H | |||||
RSLF-06-SSD | Rc1/2" | 0.6 | 21 | 500 | 250 | 500 | 25 | RSG-AO-0017G/V2 | RSG-AA-0017G/V2 |
RSLF-09-SSD | Rc1/2" | 0.9 | 32 | 500 | 250 | 500 | 25 | RSG-AO-0017G/V2 | RSG-AA-0017G/V2 |
RSLF-12-SSD | Rc1/2" | 1.2 | 42 | 600 | 310 | 500 | 30 | RSG-AO-0030G/V2 | RSG-AA-0030G/V2 |
RSLF-15-SSD | Rc1/2" | 1.5 | 53 | 600 | 310 | 500 | 30 | RSG-AO-0030G/V2 | RSG-AA-0030G/V2 |
RSLF-18-SSD | Rc1/2" | 1.8 | 64 | 600 | 310 | 500 | 30 | RSG-AO-0030G/V2 | RSG-AA-0030G/V2 |
RSLF-24-SSD | Rc3/4" | 2.4 | 85 | 750 | 360 | 550 | 50 | RSG-AO-0058G/V2 | RSG-AA-0058G/V2 |
RSLF-30-SSD | Rc3/4" | 3.0 | 106 | 750 | 360 | 550 | 50 | RSG-AO-0058G/V2 | RSG-AA-0058G/V2 |
RSLF-36-SSD | Rc3/4" | 3.6 | 127 | 750 | 360 | 550 | 55 | RSG-AO-0058G/V2 | RSG-AA-0058G/V2 |
RSLF-40-SSD | Rc3/4" | 4.0 | 141 | 750 | 360 | 550 | 55 | RSG-AO-0080G/V2 | RSG-AA-0080G/V2 |
Rated Conditions | |
Working pressure : 0.7MPag / 100psig | |
Inlet temp : 38 ℃ / 100 ℉ | |
Ambient temp : 38℃ / 100 ℉ | |
Working Range | |
Max. working pressure : 1.6MPag / 232psig | |
Max. inlet temperature : 60 ℃ / 140 ℉ | |
Max. ambient temperature : 50℃ / 122 ℉ | |
Min. ambient temperature : 5℃ / 41 ℉ | |
Avaliable | |
Higher working pressure | |
Different power supply | |
Timed drain or zero loss drain |
Correction Factors
Actual Capacity ( m³/min ) = Nominal Capacity × KA × KB × KC
Working Pressure (KA) | Mpag | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 |
psig | 44 | 58 | 73 | 87 | 102 | 116 | 131 | |
CFP | 0.76 | 0.86 | 0.92 | 0.93 | 1.00 | 1.04 | 1.08 | |
Mpag | 1.0 | 1.1 | 1.2 | 1.3 | 1.4 | 1.5 | 1.6 | |
psig | 145 | 160 | 174 | 189 | 203 | 218 | 232 | |
CFP | 1.11 | 1.15 | 1.18 | 1.22 | 1.25 | 1.28 | 1.30 |
Inlet Temperature (KB) | ℃ | 35 | 38 | 40 | 46 | 49 | 54 | 60 |
℉ | 95 | 100 | 104 | 115 | 120 | 129 | 140 | |
CFT | 1.11 | 1.00 | 0.92 | 0.76 | 0.69 | 0.56 | 0.46 |
Ambient Temperature (KC) | ℃ | 25 | 30 | 35 | 38 | 40 | 45 | 50 |
℉ | 77 | 86 | 95 | 100 | 104 | 113 | 122 | |
CFT | 1.15 | 1.10 | 1.02 | 1.00 | 0.89 | 0.79 | 0.69 |